Access Power Controller w/ Power Supply/Chargers, 16 Fused Class 2 Relay Outputs, Dual 12/24VDC P/S @ 3.5A each, FAI, LinQ2 Ready, 115VAC, BC800 Enclosure.

Maximal11F Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form “C” contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.

Additional information

Weight 39.4 lbs
Dimensions 6.25 × 19.00 × 26.00 in
Condition

New

Manufacturer

Altronix Corp.

Brand

Altronix

Production Status

Active

Features

  • Sixteen (16) independently controlled outputs Output options: a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs b) Sixteen (16) form “C” 5A rated relay outputs c) Any combination of the above
  • Sixteen (16) auxiliary power outputs (unswitched)
  • Output fuses are rated @ 3.5A
  • Filtered and electronically regulated outputs
  • Supervision: AC Fail, Battery Fail and Battery Presence, Low power shutdown
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input, b) Polarity reversal input from FACP signaling circuit
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries
  • UL Listed in the U.S. and Canada
  • CE European Conformity
  • Lifetime Warranty