FIRE-LITE ES-200X Fire Alarm Control Panel
Contact us for price breaks on large quantities!
The Fire-Lite ES-200X is a 198-point addressable fire alarm control panel that features a built-in dual path communications, programmable buttons and support for combined fire and CO addressable detection. Compatible with Fire-Lite’s devices in LiteSpeed and CLIP mode; Compatible with legacy Fire-Lite 300 Series devices in CLIP mode only. The control panel provides four Class B or four Class A NACs (Notification Appliance Circuits). Each circuit is capable of 2.5 amps of current. NAC power expandable by 3.0 amps with optional PWRMOD24 module.
Specifications
Weight | 16 lbs |
---|---|
Dimensions | 8.5 × 22.50 × 20.00 in |
Manufacturer |
Honeywell |
Brand |
Fire-Lite |
Condition |
New |
Type |
Control Panel |
Style |
Addressable |
Color |
Red |
Production Status |
Active |
Compatibility |
Features
- Listed to UL Standard 864, 10th edition
- Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Telephone Service) Central Station Communicator over AlarmNet
- Optional CELL-MOD or CELL-CAB-FL GSM Central Station
- Communicator over AlarmNet®
- Automated activation of the ECC-50/100 Emergency Command Center
- ECC-FFT Firefighter Telephone option
- Compatible with SWIFT® wireless devices
- Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address
- Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits
- Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices
- Notification Appliance Circuit End of Line resistor matching
- Four programmable function keys for ease of maintenance
- Two programmable relays and one fixed trouble relay
- Built-in Programmer
- Integral 80-character LCD display with backlighting
- Real-time clock/calendar with automatic daylight savings control
- History file with 1,000 event capacity
- Addressable sounder base compatibility
- Multi-criteria detector (smoke, heat, CO) with programmable response
- Control module delay timer
- Automatic detector sensitivity testing (NFPA 72 compliant)
- Automatic device type-code verification
- Point trouble identification
- Waterflow selection per module point
- Alarm verification selection per detector point
- Maintenance alert warns when smoke detector dust accumulation is excessive
- One-person audible or silent walk test with walk-test log and printout
- System alarm verification selection per detector point
- PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)
- Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus
- Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator
- Upload/Download of program and data via USB with optional FS-Tools Programming Utility