Notifier SFP-10UD Ten-zone 24-volt Fire Alarm Control Panel
Contact us for price breaks on large quantities!
Notifier SFP-10UD Ten-zone 24-volt Fire Alarm Control Panel.
The SFP-5UD is a five-zone FACP (Fire Alarm Control Panel) and the SFP-10UD(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “freeze” signal when the ambient temperature falls below the detector rating. Additionally, both the SFP-5UD and SFP10UD are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.
Additional information
Weight | 16 lbs |
---|---|
Dimensions | 8.50 × 22.50 × 20.00 in |
Condition |
New |
Production Status |
Obsolete |
Brand |
Notifier |
Features
- Listed to UL Standard 864, 9th edition.
- Built-in DACT (Digital Alarm Communicator/Transmitter).
- Style B (Class B) IDC (Initiating Device Circuit)
- SFP-5UD – five IDCs.
- SFP-10UD – ten IDCs.
- Style Y (Class B) NAC (Notification Appliance Circuit) – special application power
- SFP-5UD – four NACs.
- SFP-10UD – four NACs.
- Notification Appliances may be programmed as
- Silence Inhibit.
- Auto-Silence.
- Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices.
- Selective Silence (horn-strobe mute).
- Temporal or Steady Signal.
- Silenceable or Nonsilenceable.
- Optional N-CAC-5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for SFP-10UD).
- Form-C Relays for Alarm, Trouble and Supervisory
Contact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). - 3.0 A total system current for SFP-5UD.
- 7.0 A total system current for SFP-10UD.
- Optional Dress Panel DP-51050 (red)
- Optional Dress Panel DP-51050B (black).
- Optional Trim Ring TR-CE/-B for semi-flush mounting.
- 24 volt operation.
- Low AC voltage sense.
- Alarm Verification.
- PAS (Positive Alarm Sequence).
- Automatic battery trickle charger.
- Up to eight ANN-BUS annunciators:
- Optional 8 zone Relay Module N-ANN-RLY.
- Optional LED Annunciator Module N-ANN-LED.
- Optional Remote LCD Annunciator N-ANN-80.
- Optional Remote Printer Gateway N-ANN-S/PG.
- Optional LED Annunciator Driver N-ANN-I/O.
- Optional 4XTM module (conventional reverse polarity/city box transmitter)